• Delta PLC+VFD+HMI Trainer Kit (BAT-IA-03)

Model:  BAT-IA-03

  •  HMI – VFD MODBUS Drive: Delta VFD M Series Communication HMI: Delta B Series (DOP-BO7s411) nfiLearning Made Easy www.nfiautomation.org 10010 11011
  •   It Read/Write the memory addresses directly ASCII Mode Baud Rate: 9600 Parity: Even Data Length: 7 Stop Bit: 1 nfiLearning Made Easy´ MODBUS is the serial communication between various devices. ´What is MODBUS ?
  • STEPS TO LINK VFD AND HMI VIA MODBUS nfiLearning Made Easy
  • It Read/Write the memory addresses directly ASCII Mode Baud Rate: 9600 Parity: Even Data Length: 7 Stop Bit: 1 PIN WIRING Inverter HMI PIN 4 (+) 1 3 (-) 6 nfiLearning Made Easy´ MODBUS is the serial communication between various devices. ´Step 1: Wire the VFD and HMI
  • ASCII Mode Parity: Even Data Length: 7 Stop Bit: 1 Source of Frequency Command : RS 485 (Pr. 00 - 3) Source of Operation Command : RS 485 (Pr. 01 - 3) (Parameter 92 – 01) Baud Rate: 9600 (Parameter 89 – 01) nfiLearning Made Easy Step 2 Configuring VFD with Communication Parameters
  • Configuring HMI with Communication Parameters Steps to follow: 1. Start a new project in DOP Soft 2. Select your HMI Model and click NEXT 3. Enter the parameters as shown in the figure 4. Click Finish nfiLearning Made Easy
  • Create Constant elements in HMI Software for ON/OFF Now we have to create some constant elements & Slider in HMI to Read/Write the values directly in VFD Memory registers. How to create Constant? Navigate to Elements – Button – Set Constant Sample Screen nfiLearning Made Easy
  •  Understanding Memory addresses of the VFD Following image shows general memory addresses of VFD for MODBUS operation via the constant we created in HMI. MODBUS ADDRESSES READ/WRITE VALUES nfiLearning Made Easy Find more addresses in VFD manual
  • Example: VFD Operation 2000H - Calibrated Values: Following are the calibrated values you can use in the constant elements you created in HMI 0 0 0 0 0 1 K1 Stop 0 0 0 0 1 0 k2 RUN 0 0 0 0 1 1 k3 JOG 0 1 0 0 0 0 k16 FWD 1 0 0 0 0 0 K3 2 REV 1 1 0 0 0 0 k48 Toggle Direction 0 1 0 0 1 0 k18 FWD RUN 1 0 0 0 1 0 K3 4 REV RUN b5 b4 b3 b2 b1 b0 D Function nfiLearning Made Easy
  • Write address in constants elements Constant Element {Link2}1@INVERTER-2000 VFD ADDRESS for OperationHMI Link nfiLearning Made Easy
  • Memory addresses for VFD Frequency Following image shows general memory addresses of Frequency Command of VFD MODBUS ADDRES S READ/WRITE VALUES nfiLearning Made Easy
  • Linking Freq. Command address to Slider Element Following images show the general memory addresses of Frequency Command (0 ~ 50Hz) of VFD H2001 = Frequency Command 1 = 0.01 Hz 5000 = 50 Hz nfiLearning Made Easy
  •  {Link2}1@INVERTER-2104 Meter Element Following images show the memory addresses of Output Current of VFD Step 8 Reading the output current from VFD Double Click on the element to access
  • {Link2}1@INVERTER-2106 Meter Element Following images show the memory addresses of Output Voltage of VFD Step 9 Reading the output voltage from VFD Double Click on the element to access properties nfiLearning Made Easy
  •  Thank You www.nfiautomation.org nfiLearning Made Easy

Write a review

Note: HTML is not translated!
    Bad           Good
BAT-IA-03

Delta PLC+VFD+HMI Trainer Kit (BAT-IA-03)

Bangladesh Automation Technologies
2024-11-01 BDT
  • 150000.00

    Price : 150,000.00 /=

  • Ex Tax: Price : 150,000.00 /=

Tags: Delta PLC+VFD+HMI Trainer Kit (BAT-IA-03)

PLC Product

Siemens, Mitshubishi, Delta, LS, ...

HMI Product

Delta, Siemens, Mitsubishi, Omron, ...

Inverter Product

Siemens, Mitshubishi, Delta, LS, Omron, ...

PLC Data Cable

Siemens, Mitshubishi, Delta, LS, Omron, ...